Fieldeng
Electrical & Power

Electrical & Power

Fieldeng calculators for Electrical & Power. Signal color matches the app.

Electrical & Power

47 tools list this domain in the app. A tool can appear in more than one domain. The page lives under the first domain on that tool.

0–10 V to Percent Span

Where a voltage signal sits in its configured span. Defaults to 0–10 V. Not clamped.

250 Ω Loop Resistor

Voltage across a 250 Ω HART / PLC current-loop resistor.

4–20 mA Loop Burden

Voltage drop across series loop devices and remaining supply voltage.

4–20 mA PLC Raw Scaling

Raw PLC counts that represent 4–20 mA, then the configured engineering pressure.

4–20 mA to Engineering Units

Linear transmitter current to process value. Engineering fields are pressure; use generic linear scaling for other quantities.

4–20 mA to Percent Span

Where a live-zero current sits in its configured span. Over/under-range is not clamped.

AC Power Factor

Power factor from measured real and apparent power, or from P, V, and I.

ADC Counts to Voltage

Unipolar ADC: V = counts × Vref / (2^N − 1). Endpoints are 0 and full-scale.

Analog Loop Health

Loop voltage drop, remaining headroom, and how the installed resistance compares with Rmax at 20 mA (INST-10).

Automotive Voltage Check

Contextual interpretation of a measured vehicle battery voltage.

Battery Bank

Resulting voltage, capacity, and energy for identical batteries in series and parallel.

Battery Charge Time

Estimate charging time from capacity, SOC window, and charge current.

Battery Runtime

Estimate how long a battery can operate a load.

Cable Length

How much conductor that resistance represents — leftover on a spool, or length of a linear-anode header.

Cable Resistance

Conductor resistance from resistivity, length, and cross-sectional area.

Cable Voltage Drop

Voltage drop from cable current and resistance.

Conductivity ↔ Resistivity

Convert between conductivity and resistivity.

COP / EER

COP = useful thermal power / electrical input. EER = (Btu/h of cooling) / (W electrical) = COP × 3.412.

Current Density

Current density from current and exposed or active area.

DC Circuit Voltage Drop

Two-wire DC voltage drop from one-way length and conductor resistance per unit length.

DC Power Loss

Power dissipated in wiring, Ethernet PoE loops, or another resistive element.

Electrical Load Energy

Energy consumed by a constant load over time.

Engineering Units to 4–20 mA

Expected transmitter current for a known process pressure.

Fan Heat

Heat to the airstream = electrical input × heat-to-air fraction. The fraction is required — motors do not dump 100% into the duct by default.

LED Current-Limiting Resistor

Series resistor and dissipation for an LED or other voltage-dependent load.

Load Current / Power

Convert between voltage, current, and power for a DC, PoE, or unity-PF load.

Loop Current Diagnostic

Where a measured loop current sits relative to live zero/full scale, with NAMUR-style band context — not a device verdict.

Maximum Loop Resistance

Maximum series resistance a 4–20 mA loop can tolerate at full-scale current.

Ohm's Law & DC Power

Solve for voltage, current, resistance, or power from any two of the four.

Parallel Resistance

Combine two or more resistances in parallel.

Pipeline Linear Resistance

Resistance per unit length of the pipe metal from electrical resistivity and metal cross-section. Not soil resistivity or coating conductance.

Pipeline Resistance

Total metal resistance of a pipeline from linear resistance and length.

PoE Power Budget

Whether a PoE source budget covers connected PD loads. Not a PoE class lookup.

Rectifier Circuit Resistance

Effective operating circuit resistance from DC voltage and current. For a shunt millivolt rating, use Shunt Value.

Rectifier DC Power

Convert between rectifier DC voltage, current, and power.

Rectifier Efficiency

DC output power as a fraction of AC input power.

Resistance from Resistivity

Calculate conductor resistance from resistivity, length, and area.

Series Resistance

Sum two or more resistances in series.

Shunt Current

Current from measured shunt voltage and known shunt resistance.

Shunt Resistance

Shunt resistance from measured voltage and current.

Shunt Value

Shunt measurement from millivolt drop and current. Same Ohm’s-law math as Rectifier Circuit Resistance, labeled for shunt work.

Shunt Voltage

Voltage drop across a shunt from current and resistance. Display in mV or V.

Single-Phase AC Power

Real, apparent, and reactive power for a single-phase AC load.

Solar PV Energy

Estimate daily energy production from a PV array.

Three-Phase AC Power

Balanced three-phase power from line-to-line voltage and line current.

Voltage Drop

Calculate voltage drop or IR drop from current and resistance.

Voltage to ADC Counts

Nearest integer count using round-half-away-from-negative-infinity (ECMA Math.round).