Cathodic Protection
Rectifier Efficiency
DC output power as a fraction of AC input power.
Cathodic ProtectionElectrical & Power
DC output power as a fraction of AC input power.
App id: RECT-03. Reference version 1.0.
How to fill it
Fill the inputs. The tool shows the outputs.
On the tool screen, Calc is the working sheet. Presets stores values you reuse. Reference is the formula, assumptions, and provenance below.
Formula
η = PDC / PACInputs
| Name | Unit |
|---|---|
| AC input power | W |
| DC output power | W |
Outputs
| Name | Unit |
|---|---|
| Efficiency (hero result) | % |
Diagnose
This tool does not attach diagnose observations.
Assumptions
- Efficiency above 100% is reported if the entered powers imply it; check the measurements.
Provenance
- Field estimate from measured AC input and DC output. Transformer and auxiliary loads are included in PAC if measured that way.