Fieldeng
Thermal & HVAC

Overall R-Value / U-Value

Series area-normalized resistance R″ = Σ(L/k) + surface resistances. U = 1/R″. Not parallel paths.

Thermal & HVAC

Series area-normalized resistance R″ = Σ(L/k) + surface resistances. U = 1/R″. Not parallel paths.

App id: THERM-07. Reference version 1.0.

How to fill it

Fill the inputs. The tool shows the outputs.

On the tool screen, Calc is the working sheet. Presets stores values you reuse. Reference is the formula, assumptions, and provenance below.

Formula

R″ = Σ Lᵢ/kᵢ;  U = 1 / R″

Inputs

NameUnit
Layer 1 thicknessm
Layer 1 kW/m-K
Layer 2 thickness (optional)m
Layer 2 k (optional)W/m-K
Layer 3 thickness (optional)m
Layer 3 k (optional)W/m-K
Inside surface R″ (optional)m2-K/W
Outside surface R″ (optional)m2-K/W

Outputs

NameUnit
R-value (R″) (hero result)m2-K/W
U-valueW/m2-K

Diagnose

This tool does not attach diagnose observations.

Assumptions

  • Surface resistances are area-normalized (m²·K/W), not K/W.

Provenance

  • Series only. Leave unused layers blank.

On this page