Fieldeng
Fluid & Pressure

Water Hammer Screening

Joukowsky surge estimate ΔP = ρ a ΔV. Not a transient simulation.

Fluid & Pressure

Joukowsky surge estimate ΔP = ρ a ΔV. Not a transient simulation.

App id: FLUID-25. Reference version 1.0.

How to fill it

Fill the inputs. The tool shows the outputs.

On the tool screen, Calc is the working sheet. Presets stores values you reuse. Reference is the formula, assumptions, and provenance below.

Formula

ΔP = ρ a ΔV

Inputs

NameUnit
Densitykg/m3
Wave speedm/s
Velocity changem/s

Outputs

NameUnit
Transient pressure change (hero result)kPa

Diagnose

Observations are context. They do not pass or fail a structure. See Diagnose.

WhenObservationSeverity
Every resultJoukowsky screening onlyinfo

Assumptions

  • Instantaneous closure / velocity change.
  • Does not include valve time, pipe elasticity, or boundary conditions.

Provenance

  • Joukowsky equation for instantaneous velocity change.