Fieldeng
Fluid & Pressure

Valve Pressure Drop

Incompressible valve ΔP from US Cv: Q_gpm = Cv √(ΔP_psi / SG).

Fluid & Pressure

Incompressible valve ΔP from US Cv: Q_gpm = Cv √(ΔP_psi / SG).

App id: FLUID-13. Reference version 1.0.

How to fill it

Fill the inputs. The tool shows the outputs.

On the tool screen, Calc is the working sheet. Presets stores values you reuse. Reference is the formula, assumptions, and provenance below.

Formula

ΔP_psi = SG (Q_gpm / Cv)²

Inputs

NameUnit
Volumetric flowgpm
Valve Cv1
Specific gravity1

Outputs

NameUnit
Pressure drop (hero result)psi

Diagnose

Observations are context. They do not pass or fail a structure. See Diagnose.

WhenObservationSeverity
Every resultUS Cv conventioninfo

Assumptions

  • Cv is the US customary coefficient (gpm of water at 1 psi).
  • Not valve authority, cavitation, or compressible-gas sizing.

Provenance

  • ISA/US Cv liquid sizing. Liquid, turbulent, no flashing.