Fieldeng
Fluid & Pressure

Pump Head

Pump differential head from suction and discharge pressure, with optional elevation and velocity terms.

Fluid & PressureMechanical & Motion

Pump differential head from suction and discharge pressure, with optional elevation and velocity terms.

App id: FLUID-16. Reference version 1.0.

How to fill it

Fill the inputs. The tool shows the outputs.

On the tool screen, Calc is the working sheet. Presets stores values you reuse. Reference is the formula, assumptions, and provenance below.

Formula

H = (P₂ − P₁)/(ρg) + (v₂² − v₁²)/(2g) + (z₂ − z₁)

Inputs

NameUnit
Suction pressure (camera)kPa
Discharge pressure (camera)kPa
Densitykg/m3
Suction elevation (optional)m
Discharge elevation (optional)m
Volumetric flow (optional)m3/s
Suction diameter (optional)mm
Discharge diameter (optional)mm
Gravity (optional)m/s2

Outputs

NameUnit
Pump head (hero result)m
Differential pressurekPa
Pressure headm
Velocity-head contributionm
Elevation contributionm

Diagnose

This tool does not attach diagnose observations.

Assumptions

  • Suction and discharge pressures must use the same gauge/absolute convention.
  • Velocity terms apply only when flow and both diameters are entered.

Provenance

  • Steady-flow energy equation between suction and discharge gauges.