Fieldeng
Cathodic Protection

Barnes Layer Resistivity

Resistivity of one depth interval from two successive Wenner measurements.

Cathodic Protection

Resistivity of one depth interval from two successive Wenner measurements.

App id: SOIL-07. Reference version 1.0.

How to fill it

Fill the inputs. The tool shows the outputs.

On the tool screen, Calc is the working sheet. Presets stores values you reuse. Reference is the formula, assumptions, and provenance below.

Formula

ΔS = S2 − S1; R_layer = R1 R2 / (R1 − R2); ρ_layer = 2π ΔS R_layer

Inputs

NameUnit
Previous spacingft
Previous resistanceohm
Current spacingft
Current resistance (camera)ohm

Outputs

NameUnit
Layer thicknessft
Layer resistanceohm
Layer resistivity (hero result)ohm-cm

Diagnose

Observations are context. They do not pass or fail a structure. See Diagnose.

Screening bands in the app: Very Low · Low · Moderate · High · Very High.

WhenObservationSeverity
resistivity < 1,000 Ω·cmVery Lowinfo
1,000 ≤ resistivity < 3,000 Ω·cmLowinfo
3,000 ≤ resistivity < 10,000 Ω·cmModerateinfo
10,000 ≤ resistivity < 30,000 Ω·cmHighinfo
resistivity ≥ 30,000 Ω·cmVery Highinfo

Assumptions

  • Single interval extracted from the Barnes successive-layer method.
  • Throws if adjacent measured resistances are equal or nearly equal.

Provenance

  • NACE/CP2 training material describing Barnes Layer calculations.