Fieldeng
Cathodic Protection

Pipe-to-Soil Potential

Display a pipe-to-soil reading with an optional labeled reference correction.

Cathodic Protection

Display a pipe-to-soil reading with an optional labeled reference correction.

App id: MEAS-03. Reference version 1.0.

How to fill it

Fill the inputs. The tool shows the outputs.

On the tool screen, Calc is the working sheet. Presets stores values you reuse. Reference is the formula, assumptions, and provenance below.

Formula

Vpipe-soil = Vmeasured + Vcorrection

Inputs

NameUnit
Measured potential (camera)mV
Reference correction (optional)mV
Selected criterion (optional)mV

Outputs

NameUnit
Pipe-to-soil potential (hero result)mV
Selected criterionmV

Diagnose

This tool does not attach diagnose observations.

Assumptions

  • Correction defaults to zero. Criterion defaults to −850 mV when left blank.
  • Context is not a protection verdict. Polarization, IR drop, and electrode type still matter.

Provenance

  • −850 mV CSE is a common CP reference, not a Fieldeng pass/fail. Correction is applied only when entered.