Fieldeng
Cathodic Protection

Corrosion Rate from Mass Loss

Uniform penetration rate from coupon mass loss, density, area, and exposure time.

Cathodic ProtectionEngineering Fundamentals

Uniform penetration rate from coupon mass loss, density, area, and exposure time.

App id: CORR-01. Reference version 1.0.

How to fill it

Fill the inputs. The tool shows the outputs.

On the tool screen, Calc is the working sheet. Presets stores values you reuse. Reference is the formula, assumptions, and provenance below.

Formula

CR = (Δm / ρ) / (A × t)

Inputs

NameUnit
Mass lossg
Metal densitykg/m3
Exposed areacm2
Exposure timeyear

Outputs

NameUnit
Penetration rate (hero result)mm/year

Diagnose

This tool does not attach diagnose observations.

Assumptions

  • Uniform attack over the entered area. Not a pitting or remaining-life model.

Provenance

  • ASTM G102-style conversion of mass loss to a uniform penetration rate.