Fieldeng
Cathodic Protection

Barnes Survey

Layer resistances and resistivities from successive Wenner measurements.

Cathodic Protection

Layer resistances and resistivities from successive Wenner measurements.

App id: SOIL-06. Reference version 1.0.

How to fill it

Add rows as you need them. The tool uses every row you enter.

On the tool screen, Calc is the working sheet. Presets stores values you reuse. Reference is the formula, assumptions, and provenance below.

Formula

R_n,layer = R(n-1) R(n) / (R(n-1) − R(n)); ρ_n,layer = 2π S_n,layer R_n,layer

Inputs

NameUnit
Electrode spacingft
Measured resistance (camera)ohm

Outputs

NameUnit
Apparent resistivityohm-cm
Layer thicknessft
Layer resistanceohm
Layer resistivity (hero result)ohm-cm

Diagnose

Observations are context. They do not pass or fail a structure. See Diagnose.

Screening bands in the app: Very Low · Low · Moderate · High · Very High.

WhenObservationSeverity
resistivity < 1,000 Ω·cmVery Lowinfo
1,000 ≤ resistivity < 3,000 Ω·cmLowinfo
3,000 ≤ resistivity < 10,000 Ω·cmModerateinfo
10,000 ≤ resistivity < 30,000 Ω·cmHighinfo
resistivity ≥ 30,000 Ω·cmVery Highinfo

Assumptions

  • Successive Wenner measurements treated as parallel paths.
  • Spacings are strictly increasing. Adjacent equal resistances make a layer unstable.

Provenance

  • NACE/CP2 training material describing Barnes Layer calculations.
  • Seattle Public Utilities Cathodic Protection Design Standards.