Cathodic Protection
Barnes Survey
Layer resistances and resistivities from successive Wenner measurements.
Cathodic Protection
Layer resistances and resistivities from successive Wenner measurements.
App id: SOIL-06. Reference version 1.0.
How to fill it
Add rows as you need them. The tool uses every row you enter.
On the tool screen, Calc is the working sheet. Presets stores values you reuse. Reference is the formula, assumptions, and provenance below.
Formula
R_n,layer = R(n-1) R(n) / (R(n-1) − R(n)); ρ_n,layer = 2π S_n,layer R_n,layerInputs
| Name | Unit |
|---|---|
| Electrode spacing | ft |
| Measured resistance (camera) | ohm |
Outputs
| Name | Unit |
|---|---|
| Apparent resistivity | ohm-cm |
| Layer thickness | ft |
| Layer resistance | ohm |
| Layer resistivity (hero result) | ohm-cm |
Diagnose
Observations are context. They do not pass or fail a structure. See Diagnose.
Screening bands in the app: Very Low · Low · Moderate · High · Very High.
| When | Observation | Severity |
|---|---|---|
resistivity < 1,000 Ω·cm | Very Low | info |
1,000 ≤ resistivity < 3,000 Ω·cm | Low | info |
3,000 ≤ resistivity < 10,000 Ω·cm | Moderate | info |
10,000 ≤ resistivity < 30,000 Ω·cm | High | info |
resistivity ≥ 30,000 Ω·cm | Very High | info |
Assumptions
- Successive Wenner measurements treated as parallel paths.
- Spacings are strictly increasing. Adjacent equal resistances make a layer unstable.
Provenance
- NACE/CP2 training material describing Barnes Layer calculations.
- Seattle Public Utilities Cathodic Protection Design Standards.