Fieldeng
RF, Radio & Wireless

SWR ↔ Reflection Coefficient

Convert between voltage standing-wave ratio and reflection-coefficient magnitude.

RF, Radio & Wireless

Convert between voltage standing-wave ratio and reflection-coefficient magnitude.

App id: RF-10. Reference version 1.0.

How to fill it

Leave one field blank. The tool solves the rest.

On the tool screen, Calc is the working sheet. Presets stores values you reuse. Reference is the formula, assumptions, and provenance below.

Formula

Γ = (SWR − 1) / (SWR + 1)

Inputs

NameUnit
SWR1
Reflection coefficientΓ

Outputs

NameUnit
SWR (hero result)1
Reflection coefficientΓ

Diagnose

Observations are context. They do not pass or fail a structure. See Diagnose.

Screening bands in the app: Good · Fair · High · Severe.

WhenObservationSeverity
SWR < 1.5Goodinfo
SWR < 2Fairinfo
SWR < 3Highcaution
SWR ≥ 3Severewarning

Assumptions

  • Uses magnitude |Γ|. Does not retain phase.

Provenance

  • Γ = (SWR − 1) / (SWR + 1). SWR ≥ 1 and |Γ| < 1.

On this page